Contents:Installation Instructions: page 2Specifications: page 3Parts List/Torque Specs: page 4Exploded View/Kits: page 5Repair Instructions: pages 6-
INSTALLATION INSTRUCTIONS4. Use of a dampener is necessary to minimizepulsation at drive elements, plumbing, connec-tions, and other system areas. T
NOTES:1 In order to drive the pump from the side opposite the present shaftextension, simply remove the valve casing from the crankcase androtate the
ITEM PART DESCRIPTION QTY.1 08377 Crankcase 12 08378 Oil Fill Plug with Gasket 13 06479 Crankcase cover 13A 07186 Oil Sight Glass w/ Gasket 14 08380
EXPLODED VIEW - P420A-3100/5100 PUMPSP420A-3100/5100 PUMP REPAIR KITSOil Seal Kit# 09306Item Part # Description Qty.19 08366 Oil Seal 3Valve Assembly
8) Inspect all parts for wear and replace as needed.Note: The orientation of oil seal in seal case is: seal lipsface crankcase. 19 22 20 21 24 23(B)
9) Check surfaces of plungerpipe (16B).REASSEMBLY INSTRUCTIONS - P420A-3100/5100 PUMPS11) Place pressure rings andweep seals (23B) overplungers and in
P420A-3100/5100 PUMP DIMENSIONS (INCHES)GIANT INDUSTRIES LIMITED WARRANTYGiant Industries, Inc. pumps and accessories are warranted by the manufacture
Comments to this Manuals