Giant P200A User Manual

Browse online or download User Manual for Unknown Giant P200A. Giant P200A User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Series
P200A
Triplex Ceramic
Plunger Pump
Operating Instructions/
Repair and Service
Manual
For Models:
P217
P218
P219
P220
P221
P223
Contents:
Installation Instructions: page 2
Pump Specifications: pages 3-7, 10
Exploded View: page 8
Parts List: page 9
Kits & Torque Specifications: page 1 1
Trouble Shooting: page 12
Repair Instructions: pages 13-14
Dimensions: page 15
Warranty Information: back page
Updated 3/01
Page view 0
1 2 3 4 5 6 ... 15 16

Summary of Contents

Page 1

SeriesP200ATriplex CeramicPlunger PumpOperating Instructions/Repair and ServiceManualFor Models:P217P218P219P220P221P223Contents:Installation Instruct

Page 2 - INSTALLATION INSTRUCTIONS

P223A HORSEPOWER REQUIREMENTSRPM GPM 1000 PSI 2000 PSI 2320 PSI*1750 1.5 1.0 2.1 2.43200 2.8 1.9 3.8 4.53450 3.0 2.1 4.1 4.810SpecificationsModel P223

Page 3 - Model P217A

11P200A SERIES REPAIR KITSPlunger Packing KitPart # 09164 (Excluding P223)Item # Qty. Part # Description23 3 08477 V-Sleeve, weep23A 3 08087 V-Sleeve,

Page 4 - Model P218A

12PUMP SYSTEM MALFUNCTIONMALFUNCTIONThe Pressure and/orthe Delivery DropsWater in crankcaseNoisy OperationRough/PulsatingOperation withPressure DropPr

Page 5 - Model P219A

13NOTE: Always take time to lubricate all metal and nonmetal parts with a light film of oil before reassembly.This step will ensure proper fit, at the

Page 6 - Model P220A

14Reassembly sequence of the P200A series pump1) If oil seals (19) were removed, replace with seal lip towards crankcase. Lubricate seals before rep

Page 7 - Model P221A

15P200A DIMENSIONS (inches)K6

Page 8 - Exploded View - P200A Series

GIANT INDUSTRIES LIMITED WARRANTYGiant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free fromdefects in workmanship

Page 9 - P200A SERIES PARTS LIST

2INSTALLATION INSTRUCTIONS4. Use of a dampener is necessary to minimizepulsation at drive elements, plumbing, connec-tions, and other system areas.

Page 10 - Model P223A

P217A HORSEPOWER REQUIREMENTSRPM GPM 1000 PSI 1500 PSI 2000 PSI 2320 PSI*1725 1.7 1.2 1.8 2.3 2.73000 3.0 2.1 3.1 4.2 4.83200 3.2 2.2 3.3 4.4 5.13450

Page 11

P218A HORSEPOWER REQUIREMENTSRPM GPM 1000 PSI 1500 PSI 2000 PSI 2320 PSI*1150 2.2 1.5 2.3 3.1 3.61450 2.8 1.9 2.9 3.9 4.51750 3.4 2.3 3.5 4.7 5.44NOTE

Page 12 - PUMP SYSTEM MALFUNCTION

P219A HORSEPOWER REQUIREMENTSRPM GPM 1000 PSI 1500 PSI 2000 PSI 2320 PSI*1150 2.7 1.9 2.8 3.8 4.41450 3.5 2.4 3.6 4.8 5.51750 4.2 2.9 4.3 5.8 6.75Spec

Page 13

P220A HORSEPOWER REQUIREMENTSRPM GPM 1000 PSI 1500 PSI 1700 PSI 2000 PSI* 2320 PSI*1150 3.1 2.1 3.2 3.6 4.2 4.91450 3.9 2.7 4.0 4.5 5.36.21750 4.7 3.2

Page 14 - Phone: 419/531-4600

P221A HORSEPOWER REQUIREMENTSRPM GPM 1000 PSI 1500 PSI 2000 PSI* 2320 PSI*1150 1.4 1.0 1.5 2.0 2.31450 1.8 1.3 1.9 2.5 2.91750 2.2 1.5 2.3 3.0 3.57Spe

Page 15 - P200A DIMENSIONS (inches)

8Exploded View - P200A Series

Page 16 - 03/01 P200A.PM6

9ITEM PART NO. DESCRIPTION QTY.16B 08455 Plunger Pipe (Excluding P223) 316B 07778 Plunger Pipe (P223 Only) 316C 08456 Tension Screw 316D 07676 Copper

Comments to this Manuals

No comments