Contents:Installation Instructions: page 2Pump Specifications: page 3Exploded View: page 4Parts List / Kits: page 5Torque Specifications: page 5Operat
INSTALLATION INSTRUCTIONSIMPORTANT OPERATING CONDITIONSFailure to comply with any of these conditions invalidates the warranty.1. Prior to initial op
Volume ... Up to 17.6 GPMDischarge Pressure ...
EXPLODED VIEW - LP121HT PUMP4PARTS LIST - LP121HT PUMPItem Part Description Qty.1 07759 Crankcase 1
PARTS LIST - LP121HT PUMPItem Part Description Qty.1 07759 Crankcase 12 13000 Oil Filler Plug Assy. 14 06085 Crankcase Cover 15 07104 O-Ring 16 07186
Supplementary Plant Lay-Out Instructions - LP121HT PUMPPressure in Inlet SideThe stipulated NPSHR is the minimum required pressure above the vapor pre
REPAIR INSTRUCTION - LP121HT PUMPTo Check ValvesLoosen valve plugs (48). Either with needle nose pliers or with a M12 screw, which can bethreaded int
GIANT INDUSTRIES LIMITED WARRANTYGiant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free fromdefects in workmanship
Comments to this Manuals